Elite Electronics offers its Customers the highest quality fabricated fiber optic cable assemblies for use in data communications, telecommunications and/or CATV applications. Elite's applications engineers have worked closely with our strategic manufacturing partners to ensure that each fiber optic cable assembly has been designed and fabricated with component parts that meet or exceed accepted industry performance standards (e.g., ANSI/TIA/EIA, ISO/IEC, Telcordia, NTT, et cetera). Our demanding performance standards for fabricated fiber optic cable assemblies require that each assembly be serialized for testing and quality tracking purposes. Then each termination is 100% visually inspected before the fiber optic cable assembly is fully optically tested for 'insertion and return losses.' Each fabricated assembly's test readings are then rerecorded for traceability to its factory acceptance measurements. Prior to shipment, each shipping lot is inspected on a random basis using accepted industry criterion for product performance. To further ensure product quality, each shipment contains identified correlation samples complete with the data for each sample.
When ordering patch cord or custom trunk cable assemblies, customers can specify either Optical Fiber, Nonconductive, Riser (OFNR) rated cable for use in riser applications that must meet or exceed the requirements of ANSI/UL 1666-1997: Standard Test for Flame Propagation Height of Electrical and Optical-Fiber Cable Installed Vertically in Shafts and National Fire Protection Association (NFPA) NEC 2005 Art 770.51(B) FPN; or, Optical Fiber, Nonconductive, Plenum (OFNP) rated cable for use in heating and air conditioning plenum applications that must meet or exceed the requirements of ANSI/UL 1666-1997 and NFPA Standard 90A: Standard for the Installation of Air Conditioning & Ventilating Systems.
All Elite Electronics
fabricated fiber optic patch cord and custom trunk cable
assemblies are optically and electrically inspected and tested
using accepted industry test procedures as recommended by the
most current version of
ANSI/TIA/EIA-455B: Standard Test Procedure for Standard Fiber
Optic Fibers, Cables, Transducers, Sensors, Connecting &
Terminating Devices, and Other Components,
Telcordia GR-326 CORE: Generic Requirements for
Singlemode Optical Connectors & Jumper Assemblies |
|
Typical Singlemode Fiber Optic Patch Cord Performance
Requirements |
|||||||||||
|
|
|
Insertion |
Return |
Fiber |
Apex |
Repeatability |
Vibration |
Operating |
|||
|
Connector |
Type |
Loss (dB) |
Loss (dB) |
Height (nm) |
Maximum |
Maximum |
Maximum |
Temp |
|||
|
Style |
Polish |
Max |
Min |
Max |
Typ |
Max |
Min |
Offset (µm) |
Delta (dB) |
Delta (dB) |
Range |
|
FC |
UPC |
0.35 |
0.20 |
55.0 |
58.0 |
-50 |
0 |
50 |
0.1 |
0.1 |
-20 to +80°C |
|
|
APC |
0.40 |
0.25 |
65.0 |
70.0 |
-50 |
0 |
100 |
0.1 |
0.1 |
-20 to +80°C |
|
LC |
UPC |
0.35 |
0.20 |
55.0 |
58.0 |
-50 |
0 |
50 |
0.1 |
0.1 |
-20 to +80°C |
|
|
APC |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
|
SC |
UPC |
0.35 |
0.20 |
55.0 |
58.0 |
-50 |
0 |
50 |
0.1 |
0.1 |
-20 to +80°C |
|
|
APC |
0.40 |
0.25 |
65.0 |
70.0 |
-50 |
0 |
100 |
0.1 |
0.1 |
-20 to +80°C |
|
ST |
UPC |
0.35 |
0.20 |
55.0 |
58.0 |
-50 |
0 |
50 |
0.1 |
0.1 |
-20 to +80°C |
|
|
APC |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
|
Typical Multimode Fiber Optic
Patch Cord Performance Requirements |
|||||||
|
|
|
Insertion |
Return |
Repeatability |
Vibration |
Operating |
|
|
Connector |
Polish |
Loss
(dB) |
Loss
(dB) |
Maximum |
Maximum |
Temperature |
|
|
Style |
Type |
Max |
Typ |
Typical |
Delta
(dB) |
Delta
(dB) |
Range |
|
FC |
— |
0.50 |
0.30 |
25.0 |
0.15 |
0.15 |
-20 to +75°C |
|
LC |
— |
0.50 |
0.35 |
25.0 |
0.15 |
0.15 |
-20 to +80°C |
|
SC |
— |
0.50 |
0.35 |
25.0 |
0.15 |
0.15 |
-20 to +80°C |
|
ST |
— |
0.50 |
0.35 |
25.0 |
0.15 |
0.15 |
-20 to +80°C |
|
Performance Standards &
Testing Specifications |
|
|
Fiber Optic Patch Cord
Electrical & Optical |
|
|
Standard |
Standard Description |
|
Telcordia GR-326 |
Telcordia GR-326 CORE:
Generic Requirements for Singlemode Optical Connectors & Jumper
Assemblies |
|
IPC 8497-1 |
IPC-8497-1:
Cleaning Methods & Contamination Assessment for Optical Assembly |
|
ANSI/TIA/EIA-455B |
ANSI/TIA/EIA-455B:
Standard Test Procedure for Standard Fiber Optic Fibers, Cables,
Transducers, Sensors, Connecting & Terminating Devices, and Other
Components |
|
ANSI/TIA/EIA-568B.1 |
ANSI/TIA/EIA-568B.1:
Part 1 - General Requirements; Commercial Building Telecommunications
Cabling Standard |
|
ANSI/TIA/EIA‑568B.3 |
ANSI/TIA/EIA‑568B.3:
Optical Fiber Cabling Components Standard |
|
ANSI/UL 1666-1997 |
ANSI/UL 1666-1997:
Standard Test for Flame Propagation Height of Electrical and
Optical-Fiber Cable Installed Vertically in Shafts |
|
NFPA Standard 90A |
NFPA (National Fire Protection Association)
Standard 90A: Standard for the
Installation of Air Conditioning & Ventilating Systems |
|
Fiber Optic Patch Cord Optical Performance |
|
|
Measurement |
Measurement Procedure |
|
Insertion Loss |
FOTP-34 -
ANSI/TIA/EIA-455-34A: Interconnection Device Insertion Loss Test |
|
Return Loss |
FOTP-107 -
ANSI/TIA/EIA-455-107: Determination of Component Reflectance or
Link/System Return Loss Using a Test Set |
|
Attenuation |
FOTP-171 -
ANSI/TIA/EIA-455-171: Attenuation by Substitution Measurement for
Short-Length Multimode Graded-Index & Single-Mode Optical Fiber Cable
Assemblies |
|
Attenuation, Spectral |
FOTP-50 -
ANSI/TIA/EIA-455-50A: Light Launch Conditions for Long-Length
Graded-Index Optical Fiber Spectral Attenuation Measurements |
|
Aperture, Numerical |
FOTP-177 -
ANSI/TIA/EIA-455-177A: Numerical Aperture Measurement of
Graded-Index Optical Fibers |
|
Core Diameter |
FOTP-58 -
ANSI/TIA/EIA-455-58A: Core Diameter Measurement of Graded-Index
Optical Fibers |
|
Cable Length |
FOTP-60 -
ANSI/TIA/EIA‑455‑60A: Measurement of Fiber or Cable Length Using an
OTDR |
|
Output, Far Field |
FOTP-47 -
ANSI/TIA/EIA-455-47B: Output Far Field Radiation Pattern Measurement
of Optical Waveguide Fibers |
|
Output, Near Field |
FOTP-43 -
ANSI/TIA/EIA-455-43A: Output Near Field Radiation Pattern
Measurement of Optical Waveguide Fibers |
|
Fiber Optic Patch Cord Mechanical & Environmental |
|||
|
Testing Requirements & Specifications |
|||
|
Measurement |
Maximum |
Measurement |
Measurement Procedure & |
|
Acceptable |
Unit |
Performance |
|
|
Durability |
0.07 |
~ dB |
FOTP-21: 100 Mate & Unmate Cycles |
|
Humidity Cycling |
0.13 |
~ dB |
FOTP-5:
Type 1A: 240-Hours +60°C at 95% RH |
|
Temperature Cycling |
0.21 |
~ dB |
FOTP-3: 2,500-Cycles: 10°C to 60°C; Maximum Ramp; Zero Dwell Time
|
|
Cable Retention |
0.16 |
~ dB |
FOTP-6: 8-Cycles: At 1m & 3m; 133 N Ramp; 5-Second Hold Time |
|
Coupling Strength/Axial Pull |
0.04 |
~ dB |
FOTP-185:
20-pounds; 30-Second Hold Time |
|
Impact |
0.05 |
~ dB |
FOTP-2A:
8-Cycles |
|
Flex |
0.05 |
~ dB |
FOTP-1:
300-Cycles: 1-Pound; ± 45° |
|
Twist |
0.10 |
~ dB |
FOTP-36A:
10-Pounds: 0.1m ±180° |
|
Vibration |
0.11 |
~ dB |
FOTP-11:
2-Hours/Axis: 10 - 55 Hz. |
|
Insertion Force |
5.30 |
Lbs. |
FOTP-21 |
|
Extraction Force |
0.60 |
Lbs. |
FOTP-21 |
Elite Electronics requires its fabricating sources to provide a written ISO Certificate of Compliance (C of C) inclusive of the product's ISO Manufacturing Date Code, RoHS - 2002/95/EC (Directive on the Restriction of the use of Certain Hazardous Substances in Electrical & Electronic Equipment) and WEEE - 2002/96/EC (Directive on Waste Electrical & Electronic Equipment) compliance with each production shipment.